The X2-AP interface provides control interface to EnodeB SUT from the Landslide emulated ENodeB.
The X2-AP tab is available in MME Nodal Test Case when Test Activity is Intra-MME Mobility, Handoff Type is X2, and you select X2 Interface on the MME Nodal Test Configuration tab.
The X2-AP tab is available in gNB CU NSA Nodal and gNB CU Node Test Cases.
|
|
|
|
X2 Handover Settings |
|
Measurements collected for X2-AP session related processing are reported on the X2-AP Session measurement tab.
Select the proprietary version of the application from the dropdown list. Available for selection in gNB CU NSA Nodal Test Case and gNB CU Node test Cases. Options: 11.2.0/Sep2012 , 15.3.0/Sep2018, 15.7.0/Oct2019 (5G test cases) Default: 11.2.0/Sep2012 , 15.3.0/Sep2018 (5G test cases) Tcl Parameters: X2apVersion |
|||||||||||||
Startup Time (ms) |
This defines the period of time taken to wait before establishing the SCTP Transport Layer. Available for selection in gNB CU NSA Nodal Test Case. Range : 1000 to 60000 Default : 2000 Tcl Parameters: X2apStartupTime |
||||||||||||
Setup Time (ms) |
This defines the period of to wait before sending the X2 Setup Message. Available for selection in gNB CU NSA Nodal Test Case. Range : 1000 to 20000 Default : 2000 Tcl Parameters: X2apSetupTime |
||||||||||||
Response Time (ms) |
Indicates the length of time the Landslide waits for a response to an X2AP request message. Available for selection in gNB CU NSA Nodal Test Case. Range : 1000 to 60000 Default : 5000
Tcl Parameters: X2apResponseTime |
||||||||||||
EUTRA Mode Type |
Select the EUTRA mode type. Options are Frequency Division Duplex (FDD) or Time Division Duplex (TDD). In FDD mode, both uplink and downlink can transmit at the same time at different spectrum frequencies. In TDD, both uplink and downlink use the same spectrum frequencies but at different times. Per Spec 36.423. Available in gNB CU NSA Nodal test case. Options : TDD or FDD Tcl Parameters: X2apEutraModeType |
||||||||||||
FDD - Frequency Division Duplex |
The FDD Pane becomes available for input when EUTRA Mode Type = FDD. Available in gNB CU NSA Nodal test case.
|
||||||||||||
The TDD Pane becomes available for input when EUTA Mode Type = TDD. Available in gNB CU NSA Nodal test case.
|
|||||||||||||
Select to send X2 Reset only after X2 link is established in MME Nodal test case. The reset messages are exchanged between the emulated eNodeB and eNodeB (SUT).
Type: True/False Default: False Tcl Parameter: X2apSendX2ResetEn |
|||||||||||||
Reset All, Partial Reset UE to be Reset Ratio (%) Include UE X2AP ID |
Select for X2Reset in gNB CU Node TC. Available when Command Mode is Enabled. Per Specfification : O-RAN.WG5.C.1 Section 4.1.4.4 – Partial Reset (gNB-CU initiated) for EN-DC Select Reset Mode and choose Reset All or Partial Reset. When Partial Reset is selected, enter the UE to be Reset Ratio percentage. Range : 1 to 100, Default : 50 Select Include UE X2AP ID. Options : MeNB UE X2AP ID (default), SgNB UE X2AP ID, MeNB UE X2AP ID, All IDs Tcl Parameter: X2apResetModeEn Tcl Parameter: X2apResetMode Tcl Parameter: X2apResetPercent Tcl Parameter: X2apResetOption |
||||||||||||
|
Indicates the length of time/maximum time for the Handover Preparation procedure in the source eNodeB (SUT). Range : 1000 to 600000 Default : 5000 Tcl Parameters: X2apReloPrepTime |
||||||||||||
Specifies the maximum time for the protection of the overall handover procedure in the source eNodeB. Range : 1000 to 600000 Default : 5000 Tcl Parameters: X2apReloOverallTime |