T6a App Tab


The T6a App Tab in T6a interface is used between the SCEF (Services Capability Exposure Function) and the MME.  The T6a reference point is used for:

General Information

MME Node

 

General Information

Monitoring Event

Monitoring Types

Number of UEs Present in a Geographic Area

 

 

MME Location Info

 

 

Location Info Configuration  

 

MME Location Info

Related Measurements

Measurements collected for HSS related processing are reported on the T6a IP Instance and on the T6a Session report tab.


Bearer ID

Enter the bearer Id.

Range: Up to 128 characters

Default: nidd_connection_bearer_id

Tcl Parameter: ScefAppT6aBearerId

PDN Connection Charging ID

Enter the PDN connection charging ID.

Range: 0 to 4294967295

Default: 0

Tcl Parameter: ScefAppT6aPdnChargeId

Non-IP Data

Enter Non-IP data. Up to 255 characters.

Tcl Parameter: ScefAppT6aNonIpData

TDR Timer (s)

Enter TDR Timer in seconds.

Range: 0 to 30

Default: 1

Tcl Parameter: ScefAppT6aTdrTimer

Number of TDR

Enter number of TDRs.

Range: 0 to 65535

Default: 1

Tcl Parameter: ScefAppT6aNumTdr

CMR Timer (s)

Enter CMR Timer in seconds.

Range: 0 to 30

Default: 1

Tcl Parameter: ScefAppT6aCmrTimer

Number of CMR

Enter number of CMRs.

Range: 0 to 65535

Default: 1

Tcl Parameter: ScefAppT6aNumCmr

SCEF Wait Time (s)

Select to include the SCEF Wait Time in seconds.

Range: 0 to 30

Default: 0

Tcl Parameter: ScefAppT6aScefWaitTimeEn

Tcl Parameter: ScefAppT6aScefWaitTime

 

MME Node - T6a App Tab

Charging Characteristics

Select to enter Charging Characteristics.

Range: 1 to 16

Default: 16

Tcl Parameter: MmeAppT6aChargeCharEn

Tcl Parameter: MmeAppT6aChargeChar

External Identifier

Select to enter an External Identifier.

Default: 12345#(N0)@Spirent.com

Click to use the Auto-Increment Format Wizard.

Tcl Parameter: MmeAppT6aExternalIdEn

Tcl Parameter: MmeAppT6aExternalId

MSISDN

Enter MSISDN.

Tcl Parameter: MmeAppT6aMsIsdn

 

Monitoring Event - Monitoring Types

Number of UEs Present in a Geographic Area

Select to enable the number of UEs present in a geographic area.

Tcl Parameter: ScefAppT6aNumUesInGeoEn

Location Info Configuration

Select MONTE Location Type.

Option: Last Known Location

Tcl Parameter: ScefAppT6aMonLocationType

Select Accuracy.

Options: CGI-ECGI, eNB, LA-TA-RA, PRA

Default: CGI-ECGI

Tcl Parameter: ScefAppT6aMonAccuracyEn

Tcl Parameter: ScefAppT6aMonAccuracy

 

MME Location Info

E-UTRAN Cell Global Identity   Tracking Area Identity

Select the E-UTRAN Cell Global Identity and the Mobile Country Code, Mobile Network Code and E-UTRAN Cell Identity become available for input.

Select the Tracking Area Identity and the Mobile Country Code, Mobile Network Code and Tracking Area Code become available for input.

Tcl Parameter: ScefAppT6aMmeLocCgiEn

Tcl Parameter: ScefAppT6aMmeLocTaiEn

  • Mobile Country Code

Range: 000 — 999 (leading zeros are retained)

Default: 001

Tcl Parameter: ScefAppT6aMmeLocMcc

  • Mobile Network Code

Range: 000 — 999 (leading zeros are retained)

Default: 01

Tcl Parameter: ScefAppT6aMmeLocMnc

  • E-Utran Cell Identity

Range: 0 — 268435455

Default: 1

Tcl Parameter: ScefAppT6aMmeLocCellId

  • Tracking Area Code

Range: 0 — 65535

Default: 0

Tcl Parameter: ScefAppT6aMmeLocTac

 

Include User CSG Info

Select the Include User CSG Info and the Cell Access Mode, CSG ID and Membership Indication become available for input.

Tcl Parameter: ScefAppT6aMmeLocUserCsgInfoEn

  • Cell Access Mode

Options: Hybrid, Closed

Default: Closed

Tcl Parameter: ScefAppT6aMmeLocUserCsgAccessMode

  • CSG ID

Range: 0 — 4294967295

Default: 0

Tcl Parameter: ScefAppT6aMmeLocuSERCsgId

  • Membership Indication - Select to indicate membership indication.

Options: CSG Member (1) or Not CSG Member (0)

Default: CSG Member

Tcl Parameter: ScefAppT6aMmeLocUserCsgMbrshpIndEn

Tcl Parameter: ScefAppT6aMmeLocUserCsgMbrshpInd

Current Location Retrieved

Select Current Location Retrieved.

Tcl Parameter: ScefAppT6aMmeLocCurrLocRetrievedEn

Geographical Information

Select to enter Geographical Information.

Range: 1 to 8 characters

Default: 00000000

Tcl Parameter: ScefAppT6aMmeLocGeographicalEn

Tcl Parameter: ScefAppT6aMmeLocGeographical

Geodetic Information

Select to enter Geodetic Information.

Range: 1 to 10 characters

Default: 0000000000

Tcl Parameter: ScefAppT6aMmeLocGeodeticEn

Tcl Parameter: ScefAppT6aMmeLocGeodetic

Age of Location Information

Select to enter Age of Location Information.

Range: 0 to 4294967295

Default: 60

Tcl Parameter: ScefAppT6aMmeLocAgeofLocEn

Tcl Parameter: ScefAppT6aMmeLocAgeofLoc

eNodeB ID

Select to enter eNodeB.

Range: Up to 255 Characters

Tcl Parameter: ScefAppT6aMmeLocEnbIdEn

Tcl Parameter: ScefAppT6aMmeLocEnbId

 

 

^ Back to Top