In HSS Node/Nodal test case, the SBc-AP tab for SBc interface allows the user to define requests related to Emergency Broadcast System.
Message (0 to 10) |
Message (0 to 10) |
Message (0 to 10) TAI List
|
Message (0 to 10) Warning Area |
Write Replace Warning Procedure - Broadcast (HSS Nodal) | Stop Warning Procedure - Broadcast (HSS Nodal) |
Warning Indication (HSS Nodal) |
Restart/Failure Indication
|
HSS Nodal
Write Replace Warning Procedure - Broadcast | Support Write Replace Warning Indication - Checkbox True/False. Available in HSS Nodal test case.
Broadcast Scheduled Area List IE - Default - Not Included Options : Not Included, Cell Id, TAI, Emergency Area Id
Configured Cell ID - Select to include the Configured Cell ID details. Enter the Total Cell ID - Range : 1 to 300, default : 1 Enter the Cell ID. Enter the an integer (with padded 0's) 00000 to 65535. With optional auto-increment pattern #(nnnnn) or #(nnnnn C/I). Click on
|
|||||||||||||||||||||||||||
Stop Warning Procedure - Broadcast | Support Stop Warning Indication - Checkbox True/False. Available in HSS Nodal test case.
Configured Cell ID - Select to include the Configured Cell ID details. Enter the Total Cell ID - Range : 1 to 300, default : 1 Enter the Cell ID. Enter the an integer (with padded 0's) 00000 to 65535. With optional auto-increment pattern #(nnnnn) or #(nnnnn C/I). Click on
|
|||||||||||||||||||||||||||
Apply Test Data File to Warning Indications Parameters Cell ID Entry Number Range (Min - Max)
|
Select to Apply Test Data File to Warning Indications Parameters. Enabled if ("SBc-AP Version = 16.0.0/Jun2020") and ("Broadcast Scheduled Area List IE" = "TAI" or "Broadcast Cancelled Area List IE" = "TAI"). Per Release 16 of 3GPP 29.168 Cell ID Entry Number Range : The number range of Cell IDs entries in one Warning Indication message. Randomly select the value each time to indicate number of Cell ID entries to be included in one Warning Indication message. Min - The min number of Cell IDs entries in one Warning Indication message. Range : 1 to 1500, default : 1 Max - The max number of Cell IDs entries in one Warning Indication message. Range : 1 to 1500, default : 3 TDF file for configuring MCC/MNC/TAC/Cell ID entries. Example File : :WarningTAI.csv
|
|||||||||||||||||||||||||||
Restart Delay (ms) Failure Delay (ms) Number of Restart Indication Number of Failure Indication Number of Restart Indications Apply Test Data File to Restart Indications Parameters Number of Failure Indications Apply Test Data File to Failure Indications Parameters |
Restart/Failure Indication - Select to enable CBC client to send Restart Indication message and Failure Indication message via SBc interface. Per Release 16 of 3GPP 29.168 Enter the Restart Delay (ms) - The time interval between each Restart Indication message in milliseconds. Range : 1000 to 10000000 Default : 1000 Enter the Failure Delay (ms) - The time interval between each Failure Indication message in milliseconds. Range : 1000 to 10000000 Default : 1000 Number of Restart Indication - Select to enable customizing the total number of Restart Indication messages which are sent by each CBC client node. If unchecked, CBC client node continues sending Restart Indication messages. Enter the total number of Restart Indication messages. Range : 1 to 4294967295 Default : 1 Number of Failure Indication - Select to enable customizing the total number of Failure Indication messages which are sent by each CBC client node. If unchecked, CBC client node continues sending Failure Indication messages. Enter the total number of Failure Indication messages. Range : 1 to 4294967295 Default : 1 Number of Cell Information Entries for Restart Indications - Select the number - Range : 1 to 10, For each entry, enter the MCC, MNC, Starting Cell ID, Number of Cell IDs, Starting TAC, Number of TACs and eNB ID to be included in Restart Indication message. MCC - 3 digits, default = 000, MNC - 2 to 3 digits, default = 000, Starting Cell ID - Range from 0 to 268435455 (with optional auto-increment pattern #(nnnnn) or #(nnnnn C/I)) Number of Cell IDs - Range 1 to 10, default : 1 Starting TAC - Range from 00000 to 65535 (with optional auto-increment pattern #(nnnnn) or #(nnnnn C/I)) Number of TACs - Range 1 to 10, default : 1 eNB ID - Range from 0 to 268435455 , default : 0 Select to Apply Test Data File to Restart Indications Parameters. Example file : RestartInd.csv
Number of Cell Information Entries for Failure Indications - Select the number - Range : 1 to 10, For each entry, enter the MCC, MNC, Starting Cell ID, Number of Cell IDs, and eNB ID to be included in Failure Indication message. MCC - 3 digits, default = 000, MNC - 2 to 3 digits, default = 000, Starting Cell ID - Range from 0 to 268435455 (with optional auto-increment pattern #(nnnnn) or #(nnnnn C/I)) Number of Cell IDs - Range 1 to 10, default : 1 eNB ID - Range from 0 to 268435455 , default : 0 Select to Apply Test Data File to Failure Indications Parameters. Example file : FailureInd.csv
|