S6t Cln Tab


The S6t App Tab in S6t interface is used between the SCEF (Services Capability Exposure Function) and HSS.  The S6t reference point is used for:

General Information

 

 

Monitoring Event  

Monitoring Types  

 

 

 

UE Reachability Configuration  

Location Info Configuration  

 

 

Communication Pattern  

 

Related Measurements

Measurements collected for HSS related processing are reported on the S6t IP Instance and on the S6t Session report tab.


NIDD APN

Enter the NIDD APN name. Used for NIR commands.

Range: 1 to 255 characters

Default: apn1

Tcl Parameter: ScefAppS6tNiddApn

NIDD Delay (ms)

Enter NIDD Delay in ms. This field will be disabled is the T6a Interface is enabled.

Range: 0 to 4294967295

Default: 0

Tcl Parameter: ScefAppS6tNiddDelay

Include Monitoring Event Report

Select to include the monitoring event report in the Configuration-Information-Answer (CIA).

Tcl Parameter: ScefAppS6tMonEn

 

Monitoring Event

SCEF Reference ID for Deletion

Select to enter the SCEF Reference ID used for deletion.

Range: 0 to 4294967295

Default: 0

Tcl Parameter: ScefAppS6tMonRefIdDelEn

Tcl Parameter: ScefAppS6tMonRefIdDel

Monitoring Duration

Select Date/Time - UTC time.

Default: Current time

Tcl Parameter: ScefAppS6tMonDurationEn

Tcl Parameter: ScefAppS6tMonDuration

Maximum Number of Reports

Select to enter the maximum number of reports.

Range: 0 to 4294967295

Default: 10

Tcl Parameter: ScefAppS6tMonMaxReportsEn

Tcl Parameter: ScefAppS6tMonMaxReports

Monitoring Types

Select the Monitoring Types.

Select Loss Of Connectivity.

Tcl Parameter: ScefAppS6tMonLossOfConnEn

Select UE Reachability. The UE Reachability Configuration Pane becomes available for input.

  • Reachability Information

Options: Reachability for SMS, Reachability for Data, Both

Default: Reachability for SMS

Tcl Parameter: ScefAppS6tMonReachability

  • Max Latency (s)

Range: 60 — 4294967295

Default: 100

Tcl Parameter: ScefAppS6tMonMaxLatencyEn

Tcl Parameter: ScefAppS6tMonMaxLatency

  • Max Response Time (s)

Range: 0 — 4294967295

Default: 1000

Tcl Parameter: ScefAppS6tMonMaxRespTimeEn

Tcl Parameter: ScefAppS6tMonMaxRespTime

 

Select Location Reporting. The Location Info Configuration Pane becomes available for input.

  • MONTE Location Type

Options: Current Location, Last Known Location

Default: Current Location

Tcl Parameter: ScefAppS6tMonLocationType

  • Accuracy

Options: CGI-ECGI, eNB, LA-TA-RA, PRA

Default: CGI-ECGI

Tcl Parameter: ScefAppS6tMonAccuracyEn

Tcl Parameter: ScefAppS6tMonAccuracy

Select Change of IMEI-SV Association

  • Association Type

Options: IMEI Change, IMEI-SV Change

Default: IMEI Change

Tcl Parameter: ScefAppS6tMonImeiSvChangeEn

Tcl Parameter: ScefAppS6tMonImeiSvChange

 

Select Roaming Status

Tcl Parameter: ScefAppS6tMonRoamStatusEn

Select Communications Failure

Tcl Parameter: ScefAppS6tMonCommFailEn

Select Availability After DDN Failure

Tcl Parameter: ScefAppS6tMonDdnFailEn

 

Communication Pattern

Include Communication Pattern

Select to include Communication Pattern sets.

When selected the Communication Pattern pane and all the fields become available for selection.

Tcl Parameter: ScefAppS6tPatternEn

SCEF Reference ID for Deletion

Select to enter the SCEF Reference ID used for deletion.

Range: 0 to 4294967295

Default: 0

Tcl Parameter: ScefAppS6tPatternRefIdDelEn

Tcl Parameter: ScefAppS6tPatternRefIdDel

Periodic Communication Indicator

Select the communication indicator.

Options: Periodically, On Demand

Default: Periodically

Tcl Parameter: ScefAppS6tPatternPerCommInd

Communication Duration Time (s)

Available when Periodic Communication Indicator = Periodically. Select to enter the communication duration time.

Range: 0 to 4294967295

Default: 300

Tcl Parameter: ScefAppS6tPatternCommDurationEn

Tcl Parameter: ScefAppS6tPatternCommDuration

Stationary Indication

Select the stationary indication.

Options: Stationary UE, Mobile UE

Default: Stationary UE

Tcl Parameter: ScefAppS6tPatternStationaryIndEn

Tcl Parameter: ScefAppS6tPatternStationaryInd

Periodic Time (s)

Available when Periodic Communication Indicator = Periodically. Select to enter the periodic time.

Range: 0 to 4294967295

Default: 300

Tcl Parameter: ScefAppS6tPatternPeriodicTimeEn

Tcl Parameter: ScefAppS6tPatternPeriodicTime

Day-of-Week Mask

Select to enable which day of week.

Options: Sunday, Monday, Tuesday, Wednesday, Thursday, Friday and Saturday

Default: Monday

Tcl Parameter: ScefAppS6tPatternDowMaskEn

Tcl Parameter: ScefAppS6tPatternDowMask

Tcl Parameter: ScefAppS6tPatternDowSunEn

Tcl Parameter: ScefAppS6tPatternDowMonEn

Tcl Parameter: ScefAppS6tPatternDowTueEn

Tcl Parameter: ScefAppS6tPatternDowWedEn

Tcl Parameter: ScefAppS6tPatternDowThuEn

Tcl Parameter: ScefAppS6tPatternDowFriEn

Tcl Parameter: ScefAppS6tPatternDowSatEn

Time-of-Day Start

Select to enter the time of day to start. Time is in HH:MM format.

Default: 08:00

Tcl Parameter: ScefAppS6tPatternTimeOfDayStartEn

Tcl Parameter: ScefAppS6tPatternTimeOfDayStart

Time-of-Day End

Select to enter the time of day to end. Time is in HH:MM format.

Default: 09:00

Tcl Parameter: ScefAppS6tPatternTimeOfDayEndEn

Tcl Parameter: ScefAppS6tPatternTimeOfDayEnd

Reference ID Validity Time

Select to enter the reference ID validity time.

Default: Current time

Tcl Parameter: ScefAppS6tPatternRefIdValidTimeEn

Tcl Parameter: ScefAppS6tPatternRefIdValidTime

 

^ Back to Top