Number of Subscription Details |
Select the Number of Subscription Details. Available in the RIC Node test case.
Range : 1 to 16
Default : 1
Tcl Parameters: E2smNiNumSubs
Subscription
Event Trigger Style |
Select the Event trigger Style.
Options : Interface Message Event
Tcl Parameters: E2smNiSubEvtTrigStyle_1
|
Interface Message Event
Available in the RIC Node test case when Event Trigger Style = Interface Message Event.
NI Type |
Select the NI (Network Interface) Type.
Options : X2, NG, Xn, F1, E1
Tcl Parameters: E2smNiSubEvtDefNiType_1
When NI (Network Interface) Type = X2, enter the following parameters:
Select the Node Type. Options : eNB
Enter the PLMN Identity. Range : 6 Hex characters, Default : 000000
Select the eNB ID Type. Options : Macro, Home, Short Macro, Long Macro
Enter the eNB ID. Range : 0 to 2097151, default : 0
When NI (Network Interface) Type = NG or Xn or F1 or E1, enter the following parameters:
Select the NG-RAN Node Type. Options : gNB or ng-eNB (when type = Xn , F1 or E1). For type = ng-eNB, enter the ng-eNB ID Type (see eNB ID type above) and ng-eNB ID (see eNB ID above)
Enter the PLMN Identity. Range : 6 Hex characters, Default : 000000
Enter the Length. Range : 22 to 32, Default : 22
Enter the gNB ID. Range : 0 to 4294967295, default : 0
When NI (Network Interface) Type = F1, in addition to the parameters listed above, enter gNB-DU ID. Range : 0 to 68719476735, default : 0
When NI (Network Interface) Type = E1, in addition to the parameters listed above, enter gNB-CU-UP ID. Range : 0 to 68719476735, default : 0
Tcl Parameters: E2smNiSubEvtDefNiIdNodeType_1
Tcl Parameters: E2smNiSubEvtDefNiIdPlmnId_1
Tcl Parameters: E2smNiSubEvtDefNiIdEnbIdType_1
Tcl Parameters: E2smNiSubEvtDefNiIdEnbId_1
Tcl Parameters: E2smNiSubEvtDefNiIdNgRanNodeType_1
Tcl Parameters: E2smNiSubEvtDefNiIdGnbIdLen_1
Tcl Parameters: E2smNiSubEvtDefNiIdGnbId_1
Tcl Parameters: E2smNiSubEvtDefNiIdGnbDuId_1
Tcl Parameters: E2smNiSubEvtDefNiIdGnbCuUpId_1
|
NI Direction |
Select the NI (Network Interface) Direction.
Options : Incoming (default), Outgoing, Both
Tcl Parameters: E2smNiSubEvtDefNiDirection_1
|
Procedure Code |
Select the NI (Network Interface) Procedure code.
Range : 0 to 255
Default : 0
Tcl Parameters: E2smNiSubEvtDefNiMsgProcCode_1
|
Message Type |
Select the NI (Network Interface) Message Type.
Options : E2SM_NI_nothing (default), Incoming (default), E2SM_NI_initiating_message, E2SM_NI_successful_outcome, E2SM_NI_unsuccessful_outcome
Tcl Parameters: E2smNiSubEvtDefNiMsgType_1
|
Number of Protocol Tests |
Select the maximum number of Network Interface Protocol Tests in event trigger definition supported by RAN Function.
Range : 0 to 15,
Default : 0
Enter the Message Protocol IE ID for each protocol test.
Tcl Parameters: E2smNiSubEvtDefTestNum_1
Tcl Parameters: E2smNiSubEvtDefMsgProtoIeId_1_1
|
Select the Number of Actions. Available in the RIC Node test case when Event Trigger Style = Periodic.
Range : 1 to 16
Default : 1
Tcl Parameters: E2smNiSubNumActs_1
Actions
Action Type |
Select the Action Type.
Options : Report, Insert, Policy
Tcl Parameters: E2smNiSubActType_1_1
|
RIC Style Type |
Select the RIC Style Type. Each RIC Style Type has its own Action Definition Format, which is described below.
Options :
Complete Message, Partial Message
Default : Complete Message
Tcl Parameters: E2smNiSubActStyleType_1_1
|
Action Type = Report
Sequence of RAN Parameters |
This Sequence of RAN Parameters table is the same for either Complete or Partial Message. When Partial message is selected, enter the Target Protocol IE Identifier.
Range : 0 to 65535, default : 0
Click to add up to 255 RAN Parameters.
Enter the Parameter ID.
Enter the Parameter Value Type. Options : INTEGER, ENUMERATED, BOOLEAN , BIT STRING , OCTET STRING , PRINTABLE STRING
Enter the Parameter Value.
Values are validated based on the type selection listed here:
INTEGER - Range : 0-4294967295
ENUMERATED - Range : 0-4294967295
BOOLEAN - Range : 0-4294967295
BIT STRING- format: [#bits]-[hex chars], example: 16-A0FB (max 256 bits)
OCTET STRING - up to 256 Hex characters
PRINTABLE STRING - up to 256 ASCII characters
Tcl Parameters: E2smNiSubActTgtProtoIeId_1_1
Tcl Parameters: E2smNiSubActRptParamsNum_1_1_1
Tcl Parameters: E2smNiSubActRptParamsId_1_1_1
Tcl Parameters: E2smNiSubActRptParamsValueType_1_1_1
Tcl Parameters: E2smNiSubActRptParamsValue_1_1_1
|
Action Type = Policy - Message Administration
Number of RAN UE Groups |
Enter up to 10 RAN UE Groups for Policy Message Administration.
Range : 0 to 10
Default : 0
Tcl Parameters: E2smNiSubActRanUeGrpNum_1_1
|
RAN UE Group ID |
For each RAN UE Group, enter the RAN UE Group ID for Policy Message Administration.
Range : 0 to 255
Default : 0
Tcl Parameters: E2smNiSubActRanUeGrpId_1_1_1
|
RAN Parameters |
For each RAN UE Group, enter the RAN Parameters for Policy Message Administration.
Click to add up to 255 RAN Parameters.
Enter the Parameter ID.
Enter the Test Condition. Options : equal, greaterthan, lessthan, contains, present
Enter the Parameter Value Type. Options : INTEGER, ENUMERATED, BOOLEAN , BIT STRING , OCTET STRING , PRINTABLE STRING
Enter the Parameter Value.
Values are validated based on the type selection listed here:
INTEGER - Range : 0-4294967295
ENUMERATED - Range : 0-4294967295
BOOLEAN - Range : 0-4294967295
BIT STRING- format: [#bits]-[hex chars], example: 16-A0FB (max 256 bits)
OCTET STRING - up to 256 Hex characters
PRINTABLE STRING - up to 256 ASCII characters
Tcl Parameters: E2smNiSubActRanUeGrpParamsNum_1_1_1
Tcl Parameters: E2smNiSubActRanUeGrpParamsId_1_1_1_1
Tcl Parameters: E2smNiSubActRanUeGrpParamsCond_1_1_1_1
Tcl Parameters: E2smNiSubActRanUeGrpParamsValueType_1_1_1
Tcl Parameters: E2smNiSubActRanUeGrpParamsValue_1_1_1
|
RAN Imperative Policy |
For each RAN UE Group, enter the RAN Imperative Policy Parameters for Policy Message Administration.
Click to add up to 255 RAN Imperative Policy Parameters.
Enter the Parameter ID.
Enter the Parameter Value Type. Options : INTEGER, ENUMERATED, BOOLEAN , BIT STRING , OCTET STRING , PRINTABLE STRING
Enter the Parameter Value.
Values are validated based on the type selection listed here:
INTEGER - Range : 0-4294967295
ENUMERATED - Range : 0-4294967295
BOOLEAN - Range : 0-4294967295
BIT STRING- format: [#bits]-[hex chars], example: 16-A0FB (max 256 bits)
OCTET STRING - up to 256 Hex characters
PRINTABLE STRING - up to 256 ASCII characters
Tcl Parameters: E2smNiSubActRanUeGrpPolicyNum_1_1_1
Tcl Parameters: E2smNiSubActRanUeGrpPolicyId_1_1_1_1
Tcl Parameters: E2smNiSubActRanUeGrpPolicyValueType_1_1_1
Tcl Parameters: E2smNiSubActRanUeGrpPolicyValue_1_1_1
|
Action Type = Insert - Complete Message
Subsequent Action |
Enable Subsequent Action to select the Action Type and the Time to Wait.
Select the Action Type. Options : Continue (default), Halt
Select the Time to Wait.
Options : 1ms, 2ms, 5ms, 10ms, 20ms, 30ms, 40ms, 50ms, 100ms, 200ms, 500ms, 1s, 2s, 5s, 10s, 20s, 60s
Tcl Parameters: E2smNiSubActInsertSubActEn_1_1
Tcl Parameters: E2smNiSubActInsertSubActType_1_1
Tcl Parameters: E2smNiSubActInsertSubActWaitTime_1_1
|
Following Control |
Enter the Control Message Priority. Range : 0 to 5, default : 0
Select the Control Ack Request. Options : NoAck (default), Ack
Tcl Parameters: E2smNiSubActInsertMsgPriority_1_1
Tcl Parameters: E2smNiSubActInsertCtrlAckReqEn_1_1
Tcl Parameters: E2smNiSubActInsertCtrlAckReq_1_1
|
|
Number of Control Details |
Select the Number of Control Details. Available in the RIC Node test case.
Range : 1 to 16
Default : 1
Tcl Parameters: E2smNiNumCtrls
Control
RIC Style Type |
Select the RIC Style Type.
Options : Complete Message
Tcl Parameters: E2smNiCtrlStyle_1
|
Complete Message
Available in the RIC Node test case when RIC Style Type =Complete Message.
NI Type |
Select the NI (Network Interface) Type.
Options : X2, NG, Xn, F1, E1
Tcl Parameters: E2smNiCtrlNiType_1
When NI (Network Interface) Type = X2, enter the following parameters:
Select the Node Type. Options : eNB
Enter the PLMN Identity. Range : 6 Hex characters, Default : 000000
Select the eNB ID Type. Options : Macro, Home, Short Macro, Long Macro
Enter the eNB ID. Range : 0 to 2097151, default : 0
When NI (Network Interface) Type = NG or Xn or F1 or E1, enter the following parameters:
Select the NG-RAN Node Type. Options : gNB or ng-eNB (when type = Xn , F1 or E1). For type = ng-eNB, enter the ng-eNB ID Type (see eNB ID type above) and ng-eNB ID (see eNB ID above)
Enter the PLMN Identity. Range : 6 Hex characters, Default : 000000
Enter the Length. Range : 22 to 32, Default : 22
Enter the gNB ID. Range : 0 to 4294967295, default : 0
When NI (Network Interface) Type = F1, in addition to the parameters listed above, enter gNB-DU ID. Range : 0 to 68719476735, default : 0
When NI (Network Interface) Type = E1, in addition to the parameters listed above, enter gNB-CU-UP ID. Range : 0 to 68719476735, default : 0
Tcl Parameters: E2smNiCtrlNiIdNodeType_1
Tcl Parameters: E2smNiCtrlNiIdPlmnId_1
Tcl Parameters: E2smNiCtrlNiIdEnbIdType_1
Tcl Parameters: E2smNiCtrlNiIdEnbId_1
Tcl Parameters: E2smNiCtrlNiIdNgRanNodeType_1
Tcl Parameters: E2smNiCtrlNiIdGnbIdLen_1
Tcl Parameters: E2smNiCtrlNiIdGnbId_1
Tcl Parameters: E2smNiCtrlNiIdGnbDuId_1
Tcl Parameters: E2smNiCtrlNiIdGnbCuUpId_1
|
NI Direction |
Select the NI (Network Interface) Direction.
Options : Incoming (default), Outgoing, Both
Tcl Parameters: E2smNiCtrlNiDirection_1
|
Message Priority |
Select the Message Priority.
Range : 0 to 4294967295
Default : 0
Tcl Parameters: E2smNiCtrlMsgPriority_1
|
Control Ack Request |
Enable to select the Control Ack Request.
Options : NoAck (default), Ack
Tcl Parameters: E2smNiCtrlAckReqEn_1
Tcl Parameters: E2smNiCtrlAckReq_1
|
|